Natural gas
- Continuous utility supply means no on-site refilling.
- Usually the lowest runtime cost in serviced Ontario areas.
- Meter and pipe capacity must support the generator at full load.
- Gas service can still be interrupted in a wider emergency.
Build an Ontario planning budget for a permanently installed standby generator—equipment, transfer switch, fuel connection, electrical work, annual service and runtime fuel.
Estimated installed cost before HST
Generator sizing is an electrical load problem, not a square-footage shortcut. Decide what must run together, then account for the brief starting surge of motors such as central air, a well pump or sump pump.
Heating controls, refrigerator, lighting, internet, sump pump and selected receptacles—with disciplined load use.
More simultaneous essentials and one carefully managed larger load, depending on the service calculation.
A frequent planning range for homes that want broader coverage, central air and automatic load management.
Multiple HVAC zones, electric cooking, pumps or other large loads can push the design above standard air-cooled sizes.
The unit's data sheet gives consumption at several load levels. Real use changes with temperature, gas pressure, altitude and the loads cycling in your home.
U.S. fuel costs vary sharply by state, season and delivery method. The runtime model uses Angi's published full-load hourly figures as national planning anchors; check current local prices before buying.
A standby generator becomes part of the home's electrical and fuel systems. The transfer equipment must prevent backfeeding, and hired electrical work must be completed through an Ontario Licensed Electrical Contractor.
A standby generator becomes part of the home's electrical and fuel systems. Transfer equipment prevents backfeeding, but the adopted electrical code, permit process, setbacks and inspection rules vary by state and local jurisdiction.
The manual for the exact model controls. Track both calendar time and engine hours—one long outage can bring service due earlier than the annual visit.
| Task | Planning frequency | Why it matters |
|---|---|---|
| Visual status check | Monthly and after storms | Catches warning lights, debris, leaks and blocked airflow. |
| Exercise-cycle review | At the programmed interval | Confirms start, battery and controller readiness. |
| Oil and filter service | Manual interval / after extended runtime | Protects the engine; interval varies by model and use. |
| Battery and terminals | At least annually | The generator cannot protect the home if it cannot crank. |
| Transfer switch and load test | Annual professional service | Checks the complete system, not only the engine. |
| Diesel fuel quality | Per tank and service plan | Controls water, microbial growth and stale-fuel risk. |
A complete standby project often falls around C$8,000–C$25,000 before HST. A large diesel set, long trench, service upgrade or difficult site can exceed that range. Compare quotes line by line rather than comparing only the headline total.
Many homes begin in the 14–22 kW range, but there is no safe size based on floor area alone. The design must include simultaneous running loads and motor-starting surges, especially air conditioning and pumps.
The electrical work must comply with the Ontario Electrical Safety Code. A Licensed Electrical Contractor normally files the ESA notification of work, coordinates inspection and receives the Certificate of Acceptance after approval.
Natural gas is usually cheaper per running hour where utility service is available. Propane offers on-site storage and rural flexibility, but tank costs, refill pricing and winter logistics change the comparison.
Follow the manufacturer's operating and service limits. Fuel availability is only one constraint: oil level, service intervals, airflow and load matter. Inspect the unit during long outages and arrange service when the manual requires it.
No. Results are shown in Canadian dollars before Ontario HST. This makes contractor scopes easier to compare because tax is applied after the project subtotal.
HomeAdvisor reports $1,512–$8,803 for most generator-installation projects, with a $5,157 average and a high end around $13,500. Angi reports $1,600–$8,900 for most installations and says larger systems can reach $21,000 or more. A whole-home design, fuel work, panel upgrade or difficult site can push a project above the typical range.
Many homes begin in the 14–22 kW range, but floor area alone is not enough. Use a load calculation that includes simultaneous running loads and motor-starting surges, then have the design verified by a qualified installer.
Often, yes. Electrical, fuel-gas, building or zoning permits may apply. The authority having jurisdiction decides which code edition, local amendments, setbacks and inspections govern the project.
Angi's national planning figures put natural gas below propane per running hour, but local utility tariffs, propane delivery pricing, tank costs and regional availability can change the result. Check the EIA price series and local suppliers.
Follow the manufacturer's operating and service limits. Fuel availability is only one constraint: oil level, service intervals, airflow and load matter. Inspect the unit during long outages and arrange service when the manual requires it.
No. Results are shown in U.S. dollars before state and local sales taxes. Tax treatment varies by jurisdiction and contractor scope.
Canada mode uses Ontario planning ranges assembled in October 2026. U.S. mode uses published HomeAdvisor and Angi cost ranges, with BLS, Census and EIA references for price, housing-fuel and operating-cost context. Retail and fuel prices change; the calculator is deliberately a range.
U.S. project inputs use the cited published component ranges directly. Runtime fuel uses Angi's full-load hourly figures as planning anchors, scaled by selected kW and load; EIA links are provided to check current local context. No currency conversion is used.